STP1207 Automatic Tissue Processor

PRODUCT DESCRIPTION:

Automatic Tissue Processor is designed to prevent a solution to the rapidprocessing of tissue in Histology Laboratories. STP 1207 removes all the water ..from a tissue sample and replac s it with paraffin wax with optimum speed tocurtail damage to tissues caused by dehydration and shrinkage.

Specification

  • System is prudent and well-guarded, immediate and delayed start processing modes
  • Design is stout and proposes unswerving performance on smallest space.
  • Operated by Feather touch keyboard with digitally display. Display shows: Real time,date, month, audible alarm, error messages and warning codes.
  • Wax bath temperature: set temperature and attain temperature. Station no. Is display in which tissue basket is running. ·
  • Station time and lapse time shown on display.
  • All electrical switches used as ISI marked and silver coated and heavy duty.
  • Glass beakers without lip to avoid evoporisationborosil 1/2 litre capacity.
  • Leak-proof wax bath.
  • Internal parts fabricated from LM grade Aluminium.
  • Centre brass rod moving on linear bearing.
  • Heavy duty rotor motor used for agitation.
  • System has an ergonomic control panel with foil protected keyboard and LCD display to show all parameters like program number, duration, time, date, paraffin bath temperature etc.
  • Bench top carousel tissue processor with 12 station, ten reagent vessels and twoparaffin baths for single basket operation.
  • Included with wax bath over temperature (at 75°C) and under temperature cut-off facility for the safety of tissues.
  • Has agitation in 3 sec intervals with on/off function for through and even mixing ofregents
  • Auto restart function is available

   TECHNICAL PARAMETERS

  • STP 2107 Comes with storage facility of 9 or more freely selectable programs. Programs include selection of
  • infiltration time, agitation, facility, basket selection facility etc. ·
  • Provided with locking facility for user to avoid inadvertent change of the process parameters during
  • operation. ·
  • Power supply – operable at 230v, 50 Hz, inbuilt battery backup system for at least 30 minutes in case of
  • power failure ·
  • Drain time of 60sec in each station of reduce carry over contamination ·
  • Programmable immersion time from 1 minutes to 99 hours: 59 minutes) ·
  • Delayed start up function to a maximum of 9 days ·
  • Facility of beaker being automatically immersed in a station during the Power failure(Optional) ·
  • Reagent vessel tops and charcoal- enhanced ventilation help control processing vapours ·
  • Up to 7 different processing programs maintained and basket has capacity of 100 cassettes ·
  • Facility of manual lifts the carousal and removable tissues in case of long power failure ·
  • USFDA/ European CE certified
  • STANDARD ACCESSORIES:
  • Main unit- One
  • Tissue Basket- Two
  • Wax Bath- Two
  • Main Lead- One
  • Dust Cover- One
  • Tissue Capsule Small & medium- Twenty Five
  • Glass Beaker- Twelve
  • Glass fuse- Two
  • Instruction manual –one ………. (INSTRUMENT SUPPLIED IN CARD BOARD BOX WITH STYOFOAM
  • SHEET AND WOODEN CASE)